Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System
Keine Angabe KPA15

VB plus TVA
2.100 EUR
Stare
Utilizat
Locație
Borken Germania
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA15
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA15
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA15
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA15
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA15
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA15
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA15
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA15
more Images
Keine Angabe KPA15
Keine Angabe KPA15
Keine Angabe KPA15
Keine Angabe KPA15
Keine Angabe KPA15
Keine Angabe KPA15
Keine Angabe KPA15
Keine Angabe KPA15

Preț și locație

VB plus TVA
2.100 EUR
Locație:
Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland Germania
Sunați

Detalii despre ofertă

ID anunț:
A405-0120
Număr de referință:
20560
Actualizare:
ultima dată la 03.11.2026

Descriere

Betschart Swiss Transformer Core Testing System KPA 15 – Isolation Transformer Test Core Testing System

Function
The output voltage, which can be continuously adjusted manually by means of a rotary knob, is directly applied to the excitation coils of the test core.
This is intended to create a homogeneous electromagnetic field in the air gap of the test core, with which core material inserted into the air gap can be characterized.
The basic operation of the core testing system is performed via the switch and display elements on the front panel at the front of the test carriage.

Technical data
Input voltage: 2 x 400 V – 50/60 Hz
Input current: 38.3 A maximum
Output voltage: 0 … 230 V
Output current: 65 A maximum
Measurements: Moving-coil voltmeter 0 … 500V for input voltage
Moving-coil voltmeter 0 … 250V for output voltage
Moving-coil ammeter 0 … 40/80A for input current
Moving-coil ammeter 0 … 75/150A for output current
Laboratory sockets for external voltage measurement, direct, 1:1
Circuit breaker, 2-pole, 63A, characteristic B
Voltage measurement, output voltage
Current measurement, output current
Voltage measurement, input voltage
Current measurement, input current
Laboratory sockets for external current measurement, current transformer 50A/5A
Current measurement, current transformer 75A/5A, output side
Main and emergency stop switch

Manufacturer’s price: €27,000 gross
Blsdped Nxhksfx Aiaop

Matching adjustable transformers can be found in our shop.

You can find more items – new and used – in our shop!
International shipping costs available upon request!

Anunțul a fost tradus automat. Pot exista erori de traducere.

Furnizor

Înregistrat din: 2008

531 Anunțuri online

Sunați

Trimite solicitare

Terenus 
Germania
Austria
Elveția
Statele Unite ale Americii
Regatul Unit
Franța
Belgia
Spania
Mexic
Italia
Olanda
Polonia
Federația Rusă
Belarus (Republica Belarus)
Ucraina
Estonia
Turcia
Noua Zeelandă
Irlanda
Republica Cehă
Danemarca
Finlanda
Suedia
Norvegia
Luxemburg
Grecia
Lituania
Letonia
Islanda
Portugalia
Brazilia
Venezuela
Argentina
Ungaria
Slovacia
România
Moldova
Slovenia
Serbia
Muntenegru
Albania
Croația
Bulgaria
Macedonia de Nord
Bosnia şi Herţegovina
Israel
Egipt
Maroc
India
Indonezia
Coreea de Sud
Japonia
Thailanda
Malaezia
Vietnam
China, Republica Populară
Taiwan
Iran
Bangladeș
Notă: Cererea dvs. va fi transmisă tuturor vânzătorilor din categoria de utilaje. Prin aceasta puteți primi foarte multe oferte.
Solicitarea nu a putut fi trimisă. Vă rugăm să încercați din nou mai târziu.

Telefon & Fax

+49 2862 ... anunțuri