New digitally controlled MFC mass flow controller for gas, SLA5800 Biotech MassFlowControllerBROOKS INSTRUMENT
SLA585081BAB1A2S1
New digitally controlled MFC mass flow controller for gas, SLA5800 Biotech MassFlowController
BROOKS INSTRUMENT
SLA585081BAB1A2S1
Preț fix plus TVA
980 EUR
Stare
Utilizat
Locație
Hessisch Lichtenau 

Date de bază
- Denumirea mașinii:
- New digitally controlled MFC mass flow controller for gas, SLA5800 Biotech MassFlowController
- Producător:
- BROOKS INSTRUMENT
- Model:
- SLA585081BAB1A2S1
- Stare:
- folosit
Preț și locație
Preț fix plus TVA
980 EUR
- Locație:
- 37235 Hessisch Lichtenau

Sunați
Detalii despre ofertă
- ID anunț:
- A172-08372
- Număr de referință:
- 61764
- Actualizare:
- ultima dată la 11.09.2026
Descriere
SLA5800 Biotech - MFC - Digitally controlled mass flow controller for gas, Mass Flow Controller
elastomer-sealed mass flow controller, flow control, flow meter, flow controller, thermal mass flow
BROOKS INSTRUMENT Type SLA585081BAB1A2S1
Ser. No. 01C00500222
Year of manufacture 2020 (new / unused in original packaging)
SLA5800 Biotech series
Dkodjuqgbyopfx Aqpsw
Option package Biotech Premium Packet Code T
Mains connection 13.5 - 27 VDC (plug M8, 5 pin, male)
Power consumption max. 10 watts
PROFINET interface (2x RJ-45)
Visual display 2 LEDs (NET / MOD)
Gas connection 6 mm Swagelok
Valve design Normally closed
User gas O2 (oxygen) Active - Multiple / O2 (oxygen), N2 (nitrogen), CO2 (carbon dioxide), AIR (air)
Calibration gas N2 (nitrogen)
Flow control ranges (full scale) 20000 sccm (20 liters / minute)
Maximum inlet pressure 4500 psi (300 bar)
Normal operation Pressure differential 60 psig (4 bar)
Control range 2% to 100% of full scale (range of mechanism)
Typical accuracy from 20 to 100 % ± 0.9 % of set point for 20 to 100 % of full scale
Typical accuracy from 2 to 20 % ± 0.18 % of full scale for 2 to 20 % of full scale
Repeatability ± 0.2 % of the measured value
Resolution 0.1 % of full scale
Typical response time of the controller
Anunțul a fost tradus automat. Pot exista erori de traducere.
elastomer-sealed mass flow controller, flow control, flow meter, flow controller, thermal mass flow
BROOKS INSTRUMENT Type SLA585081BAB1A2S1
Ser. No. 01C00500222
Year of manufacture 2020 (new / unused in original packaging)
SLA5800 Biotech series
Dkodjuqgbyopfx Aqpsw
Option package Biotech Premium Packet Code T
Mains connection 13.5 - 27 VDC (plug M8, 5 pin, male)
Power consumption max. 10 watts
PROFINET interface (2x RJ-45)
Visual display 2 LEDs (NET / MOD)
Gas connection 6 mm Swagelok
Valve design Normally closed
User gas O2 (oxygen) Active - Multiple / O2 (oxygen), N2 (nitrogen), CO2 (carbon dioxide), AIR (air)
Calibration gas N2 (nitrogen)
Flow control ranges (full scale) 20000 sccm (20 liters / minute)
Maximum inlet pressure 4500 psi (300 bar)
Normal operation Pressure differential 60 psig (4 bar)
Control range 2% to 100% of full scale (range of mechanism)
Typical accuracy from 20 to 100 % ± 0.9 % of set point for 20 to 100 % of full scale
Typical accuracy from 2 to 20 % ± 0.18 % of full scale for 2 to 20 % of full scale
Repeatability ± 0.2 % of the measured value
Resolution 0.1 % of full scale
Typical response time of the controller
Anunțul a fost tradus automat. Pot exista erori de traducere.
Trimite solicitare
Telefon & Fax
+49 5602 ... anunțuri
Anunțul dvs. a fost șters cu succes